Our WA-Perkins power generators 9-665 kVA – 1.500 r.p.m – diesel – watercooled
Power generator |
kVA 100 % PRP* |
Motortype |
WA-P 9 |
9 | 403A-11G1 |
WA-P 13 |
13 | 403A-15G1 |
WA-P 20 |
20 | 404A-22G1 |
WA-P 30 |
30 | 1103A-33G1 |
WA-P 45 |
45 | 1103A-33TG1 |
WA-P 60 |
60 | 1103A-33TG2 |
WA-P 80 |
80 | 1104A-44TG2 |
WA-P 105 |
105 | 1104C-44TAG2 |
WA-P 130 |
130 | 1106A-70TG1 |
WA-P 150 |
150 | 1106A-70TAG2 |
WA-P 180 |
180 | 1106A-70TAG3 |
WA- P 200 |
200 | 1106A-70TAG4 |
WA-P 275 |
275 | 1606A-E93TAG4 |
WA-P 300 |
300 | 1606A-E93TAG5 |
WA-P 350 |
350 | 2205A-E13TAG2 |
WA-P 400 |
400 | 2205A-E13TAG3 |
WA-P 450 | 450 | 2506A-E15TAG1 |
WA-P 500 | 500 | 2506A-E15TAG2 |
WA-P 615 | 615 | 2806A-E18TAG1A |
WA-P 665 | 665 | 2806A-E18TAG2 |
*Prime Power PRP. Maximum power for variable load, no time limit per year. The average 24 hours operation should not exceed 80% of that power. For control purposes an thrust harder Maschinery is an overload of 10% for 1 hour within 12 hours permitted. Mode according to ISO 8528. The maintenace is to be considered.
Power generator |
Power KWm. |
Consumption 75 % Last PRP |
WA-P 9 |
8,40 KW | 2,30 L/h |
WA-P 13 |
12,00 KW | 2,80 L/h |
WA-P 20 |
18,40 KW | 4,00 L/h |
WA-P 30 |
27,60 KW | 5,40 L/h |
WA-P 45 |
41,50 KW | 8,20 L/h |
WA-P 60 |
54,00 KW | 10,40 L/h |
WA-P 80 |
71,90 KW | 14,00 L/h |
WA-P 105 |
89,00 KW | 17,01 L/h |
WA-P 130 |
118,70 KW | 24,01 L/h |
WA-P 150 |
131,00 KW | 25,80 L/h |
WA-P 180 |
157,70 KW | 31,00 L/h |
WA-P 200 |
191,30 KW | 35,00 L/h |
WA-P 275 |
217,00 KW | 36,00 L/h |
WA-P 300 |
239,00 KW | 47,00 L/h |
WA-P 350 |
304,30 KW | 54,00 L/h |
WA-P 400 |
349,00 KW | 62,00 L/h |
WA-P 450 | 396,00 KW | 72,00 L/h |
WA-P 500 | 435,00 KW | 81,00 L/h |
WA-P 615 | 522,00 KW | 90,00 L/h |
WA-P 665 | 565,00 KW | 97,00 L/h |
“G” on sled frame
Stationary version (open type) sled frame “G”
Power generator |
Fueltank L |
Length mm |
WA-P 9 “G” | 80 | 1.300 |
WA-P 13 “G” | 80 | 1.300 |
WA-P 20 “G” | 80 | 1.300 |
WA-P 30 “G” | 105 | 1.700 |
WA-P 45 “G” | 105 | 1.700 |
WA-P 60 “G” | 192 | 1.900 |
WA-P 80 “G” | 192 | 1.900 |
WA-P 105 “G” | 192 | 1.900 |
WA-P 130 “G” | 320 | 2.360 |
WA-P 150 “G” | 320 | 2.360 |
WA-P 180 “G” | 320 | 2.360 |
WA-P 200 “G” | 320 | 2.360 |
WA-P 275 “G” | 490 | 3.000 |
WA-P 300 “G” | 531 | 3.000 |
WA-P 350 “G” | 531 | 3.000 |
WA-P 400 “G” | 531 | 3.000 |
WA-P 450 “G” | 558 | 3.500 |
WA-P 500 “G” | 558 | 3.500 |
WA-P 615 “G” | 558 | 3.500 |
WA-P 665 “G” | 558 | 3.500 |
Power generator |
Width mm |
Height mm |
WA-P 9 “G” | 580 | 1.298 |
WA-P 13 “G” | 580 | 1.298 |
WA-P 20 “G” | 580 | 1.383 |
WA-P 30 “G” | 730 | 1.634 |
WA-P 45 “G” | 730 | 1.615 |
WA-P 60 “G” | 900 | 1.955 |
WA-P 80 “G” | 900 | 1.969 |
WA-P 105 “G” | 900 | 1.969 |
WA-P 130 “G” | 1.035 | 1.933 |
WA-P 150 “G” | 1.035 | 1.933 |
WA-P 180 “G” | 1.035 | 1.933 |
WA-P 200 “G” | 1.035 | 1.933 |
WA-P 275 “G” | 1.200 | 1.834 |
WA-P 300 “G” | 1.200 | 2.160 |
WA-P 350 “G” | 1.200 | 2.163 |
WA-P 400 “G” | 1.200 | 2.141 |
WA-P 450 “G” | 1.300 | 2.097 |
Power generator |
Weight KG |
WA-P 9 “G” | 400 |
WA-P 13 “G” | 423 |
WA-P 20 “G” | 475 |
WA-P 30 “G” | 700 |
WA-P 45 “G” | 820 |
WA-P 60 “G” | 1.020 |
WA-P 80 “G” | 1.220 |
WA-P 105 “G” | 1.425 |
WA-P 130 “G” | 1.442 |
WA-P 150 “G” | 1.480 |
WA-P 180 “G” | 1.510 |
WA-P 200 “G” | 1.560 |
WA-P 275 “G” | 2.005 |
WA-P 300 “G” | 2.020 |
WA-P 350 “G” | 2.840 |
WA-P 400 “G” | 3.200 |
WA-P 450 “G” | 3.240 |
WA-P 500 “G” | 3.560 |
WA-P 615 “G” | 4.175 |
WA-P 665 “G” | 4.300 |
“S” Silenced
Silenced version (with insulation) “S”
Power generator |
Fueltank L |
Length mm |
WA-P 9 “S” | 47 | 1.600 |
WA-P 13 “S” | 47 | 1.600 |
WA-P 20 “S” | 85 | 2.000 |
WA-P 30 “S” | 85 | 2.000 |
WA-P 45 “S” | 85 | 2.500 |
WA-P 60 “S” | 85 | 2.500 |
WA-P 80 “S” | 220 | 2.950 |
WA-P 105 “S” | 220 | 2.950 |
WA-P 130 “S” | 220 | 2.950 |
WA-P 150 “S” | 220 | 2.950 |
WA-P 180 “S” | 360 | 3.600 |
WA-P 200 “S” | 360 | 3.600 |
WA-P 275 “S” | 360 | 4.200 |
WA-P 300 “S” | 534 | 4.200 |
WA-P 350 “S” | 534 | 4.200 |
WA-P 400 “S” | 534 | 4.200 |
WA-P 450 “S” | 534 | 4.860 |
WA-P 500 “S” | 1.000 | 4.860 |
WA-P 615 “S” | 1.000 | 4.860 |
Power generator |
Width mm |
Height mm |
WA-P 9 “S” | 900 | 1.132 |
WA-P 13 “S” | 900 | 1.132 |
WA-P 20 “S” | 950 | 1.353 |
WA-P 30 “S” | 950 | 1.353 |
WA-P 45 “S” | 900 | 1.955 |
WA-P 60 “S” | 900 | 1.955 |
WA-P 80 “S” | 1.100 | 1.760 |
WA-P 105 “S” | 1.100 | 1.760 |
WA-P 130 “S” | 1.100 | 1.760 |
WA-P 150 “S” | 1.100 | 1.760 |
WA-P 180 “S” | 1.350 | 2.040 |
WA-P 200 “S” | 1.350 | 2.040 |
WA-P 275 “S” | 1.600 | 2.245 |
WA-P 300 “S” | 1.600 | 2.245 |
WA-P 350 “S” | 1.600 | 2.245 |
WA-P 400 “S” | 1.600 | 2.245 |
WA-P 450 “S” | 2.050 | 2.585 |
WA-P 500 “S” | 2.050 | 2.585 |
WA-P 615 “S” | 2.050 | 2.585 |
WA-P 665 “S” | 2.050 | 2.585 |
Power generator |
Weight KG |
WA-P 9 “S” | 615 |
WA-P 13 “S” | 656 |
WA-P 20 “S” | 800 |
WA-P 30 “S” | 860 |
WA-P 45 “S” | 1.180 |
WA-P 60 “S” | 1.280 |
WA-P 80 “S” | 1.620 |
WA-P 105 “S” | 1.760 |
WA-P 130 “S” | 1.900 |
WA-P 150 “S” | 2.000 |
WA-P 180 “S” | 2.450 |
WA-P 200 “S” | 2.800 |
WA-P 275 “S” | 3.640 |
WA-P 300 “S” | 3.650 |
WA-P 350 “S” | 4.050 |
WA-P 400 “S” | 4.580 |
WA-P 450 “S” | 4.640 |
WA-P 500 “S” | 6.440 |
WA-P 615 “S” | 6.500 |
WA-P 665 “S” | 6.550 |
All data in basic model or series delivery
Basic equipment: Perkins power generator
Power generator: The complete power generator is mounted on a steel base frame. On the steel base frame are specially designed devices, for lifting with a crane or Forklift. The diesel engine and the alternator are connected to a SAE-flange, that even a longer period of operation no possibility of an adjustment exists. The daily fuel tank is integrated in the steel base frame. The starter batteries of 12 or 24 volts are fixed on the steel base frame. Preheating-system 230 Volt DC.
Engine: Perkins industrial diesel 4-stroke direct injection, liquid cooled 1.500 rpm (50 Hz). Low oil and fuel consumption with long maintenance intervals make a very economic engine application.
Alternator: Mecc Alte alternator, brushless self-exciting, self-regulating with electronic voltage regulator (AVR) according to VDE 0530, 400/230 volts, 4-pole, insulation class H.
Control Panel: Manual start-stop-system with engine shutdown during monitoring, when low oil pressure (LOP), High temperate (HWT) and overspeed. Alternator switch, 3-pole with thermal and magnetic protection. Frequency meter, hours counter, voltmeter, ampere meter, optical and acoustic alarm. Electronic engine speed governor, AMF automatic control panel with ATS, for parallel operation with the mains supply or peak looping operation.
Tank: 24h fuel tank, automatic fuel-fill-system.
Trailer: 1 or 2 axle trailer.
Options: For all power generators is a wide range of accessories available.
Technical changes: We keep ahead.