Our WA-Deutz power generator – 20-500 kVA – 1.500 r.p.m – diesel- watercooled
Power generator |
kVA 100 % PRP* |
Motortype |
WA-D 20 | 20 | F 3 M 2011 |
WA-D 30 |
30 | F 4 M 2011 |
WA-D 40 | 40 | BF 4 M 2011 |
WA-D 60 | 60 | BF 4 M 2011 C |
WA-D 85 | 85 | BF 4 M 1013 E |
WA-D 100 | 105 | BF 4 M 1013 EC |
WA-D 130 | 130 | BF 4M 1013 FC |
WA-D 150 | 150 | BF 6 M 1013 EC |
WA-D 180 | 180 | BF 6 M 1013 FCP |
WA-D 200 | 200 | BF 6 M 1013 FCP |
WA-D 250 | 250 | TCD 2013 L06-4V |
WA-D 300 |
300 | BF 6 M 1015 C |
WA-D 380 |
380 | BF 6 M 1015 CP |
WA-D 430 |
430 | BF 8 M 1015 C |
WA-D 450 |
450 | BF 8 M 1015 C |
WA-D 500 |
500 | BF 8 M 1015 CP |
*Prime Power PRP. Maximum power for variable load, no time limit per year. The average 24 hours operation should not exceed 80% of that power. For control purposes an thrust harder Maschinery is an overload of 10% for 1 hour within 12 hours permitted. Mode according to ISO 8528. The maintenace is to be considered.
Power generator |
Power KWm. |
Consumption 100 % Last PRP |
WA-D 20 | 20 KW | 5,76 L/h |
WA-D 30 |
27,6 KW | 7,06 L/h |
WA-D 40 | 36,4 KW | 9,10 L/h |
WA-D 60 | 52,0 KW | 13,24 L/h |
WA-D 85 | 78,5 KW | 19,99 L/h |
WA-D 100 | 91,1 KW | 21,82 L/h |
WA-D 130 | 112 KW | 29,40 L/h |
WA-D 150 | 138,1 KW | 32,00 L/h |
WA-D 180 | 159,8 KW | 45,90 L/h |
WA-D 200 | 178,6 KW | 45,63 L/h |
WA-D 250 | 250 KW | 49,90 L/h |
WA-D 300 |
271 KW | 63,00 L/h |
WA-D 380 |
327 KW | 81,00 L/h |
WA-D 430 |
369 KW | 88,00 L/h |
WA-D 450 |
396 KW | 94,00 L/h |
WA-D 500 |
441 KW | 110,00 L/h |
Power generator |
Datasheet |
WA-D 20 | |
WA-D 30 |
|
WA-D 40 | |
WA-D 60 | |
WA-D 85 | |
WA-D 100 | |
WA-D 130 | |
WA-D 150 | |
WA-D 180 | |
WA-D 200 | |
WA-D 250 | |
WA-D 300 |
|
WA-D 380 |
|
WA-D 430 |
|
WA-D 450 |
|
WA-D 500 |
“G” On sled frame
Stationary version (open type) sled frame “G”
Power generator |
Fueltank L |
Lenghth mm |
WA-D 20 “G” | 80 | 1.400 |
WA-D 30 “G” | 105 | 1.700 |
WA-D 40 “G” | 105 | 1.700 |
WA-D 60 “G” | 192 | 1.900 |
WA-D 85 “G” | 195 | 2.050 |
WA-D 100 “G” | 212 | 2.050 |
WA-D 130 “G” | 224 | 2.250 |
WA-D 150 “G” | 236 | 2.500 |
WA-D 180 “G” | 236 | 2.500 |
WA-D 200 “G” | 236 | 2.500 |
WA-D 250 “G” | 490 | 3.000 |
WA-D 300 “G” | 562 | 2.750 |
WA-D 380 “G” | 562 | 2.750 |
WA-D 430 “G” | 550 | 3.000 |
WA-D 450 “G” | 550 | 3.000 |
WA-D 500 “G” | 550 | 3.000 |
Power generator |
Width mm |
Height mm |
WA-D 20 “G” | 760 | 1.560 |
WA-D 30 “G” | 730 | 1.520 |
WA-D 40 “G” | 730 | 1.406 |
WA-D 60 “G” | 900 | 1.625 |
WA-D 85 “G” | 930 | 1.683 |
WA-D 100 “G” | 930 | 1.717 |
WA-D 130 “G” | 1.035 | 1.475 |
WA-D 150 “G” | 1.035 | 1.607 |
WA-D 180 “G” | 1.035 | 1.840 |
WA-D 200 “G” | 1.035 | 1.840 |
WA-D 250 “G” | 1.200 | 1.795 |
WA-D 300 “G” | 1.515 | 2.252 |
WA-D 380 “G” | 1.515 | 2.380 |
WA-D 430 “G” | 1.815 | 2.406 |
WA-D 450 “G” | 1.815 | 2.410 |
WA-D 500 “G” | 1.815 | 2.406 |
Power generator |
Weight KG |
WA-D 20 “G” | 550 |
WA-D 30 “G” | 640 |
WA-D 40 “G” | 720 |
WA-D 60 “G” | 820 |
WA-D 85 “G” | 1.240 |
WA-D 100 “G” | 1.300 |
WA-D 130 “G” | 1.460 |
WA-D 150 “G” | 1.580 |
WA-D 180 “G” | 1.620 |
WA-D 200 “G” | 1.820 |
WA-D 250 “G” | 2.200 |
WA-D 300 “G” | 2.940 |
WA-D 380 “G” | 3.260 |
WA-D 430 “G” | 3.300 |
WA-D 450 “G” | 3.800 |
WA-D 500 “G” | 4.030 |
“S” Silenced
Silenced version (with insulation) “S”
Power generator |
Fueltank L |
db(A)* 7 Meter |
WA-D 20 “S” | 85 | 60 |
WA-D 30 “S” | 85 | 66 |
WA-D 40 “S” | 85 | 66 |
WA-D 60 “S” | 85 | 66 |
WA-D 85 “S” | 220 | 64 |
WA-D 100 “S” | 220 | 70 |
WA-D 130 “S” | 220 | 70 |
WA-D 150 “S” | 360 | 72 |
WA-D 180 “S” | 360 | 69 |
WA-D 200 “S” | 360 | 69 |
WA-D 250 “S” | 360 | 69.4 |
WA-D 300 “S” | 534 | 72 |
WA-D 380 “S” | 534 | 72 |
WA-D 430 “S” | 1.000 | 72 |
WA-D 450 “S” | 1.000 | 76 |
WA-D 500 “S” | 1.000 | 76 |
* db(A) measured at 7 meters as the average of all-round measurement at 7 measuring points
Power generator |
Length mm |
Width mm |
WA-D 20 “S” | 2.000 | 950 |
WA-D 30 “S” | 2.000 | 950 |
WA-D 40 “S” | 2.000 | 950 |
WA-D 60 “S” | 2.500 | 1.100 |
WA-D 85 “S” | 2.950 | 1.100 |
WA-D 100 “S” | 2.950 | 1.100 |
WA-D 130 “S” | 2.950 | 1.100 |
WA-D 150 “S” | 2.950 | 1.110 |
WA-D 180 “S” | 3.600 | 1.350 |
WA-D 200 “S” | 3.600 | 1.350 |
WA-D 250 “S” | 3.600 | 1.350 |
WA-D 300 “S” | 4.200 | 1.600 |
WA-D 380 “S” | 4.200 | 1.600 |
WA-D 430 “S” | 4.860 | 2.060 |
WA-D 450 “S” | 4.860 | 2.060 |
WA-D 500 “S” | 4.860 | 2.060 |
Power generator |
Height mm |
Weight KG |
WA-D 20 “S” | 1.353 | 875 |
WA-D 30 “S” | 1.353 | 946 |
WA-D 40 “S” | 1.353 | 962 |
WA-D 60 “S” | 1.455 | 1.440 |
WA-D 85 “S” | 1.759 | 1.780 |
WA-D 100 “S” | 1.759 | 1.840 |
WA-D 130 “S” | 1.759 | 2.120 |
WA-D 150 “S” | 1.759 | 2.350 |
WA-D 180 “S” | 2.040 | 2.960 |
WA-D 200 “S” | 2.040 | 3.060 |
WA-D 250 “S” | 2.040 | 3.340 |
WA-D 300 “S” | 2.245 | 4.005 |
WA-D 380 “S” | 2.245 | 4.460 |
WA-D 430 “S” | 2.630 | 6.000 |
WA-D 450 “S” | 2.630 | 6.100 |
WA-D 500 “S” | 2.630 | 6.380 |
All data in basic model or series delivery
Basic equipment Deutz power generator
GenSet: The complete gen set is mounted on a steel base frame. On the steel base frame are specially designed devices, for lifting with a crane or Forklift. The diesel engine and the alternator are connected to a SAE-flange, that even a longer period of operation no possibility of an adjustment exists. The daily fuel tank is integrated in the steel base frame. The starter batteries of 12 or 24 volts are fixed on the steel base frame. Preheating-system 230 Volt DC.
Engine: Deutz industrial diesel 4-stroke direct injection, liquid cooled 1.500 rpm (50 Hz). Low oil and fuel consumption with long maintenance intervals make a very economic engine application.
Alternator: Mecc Alte alternator, brushless self-exciting, self-regulating with electronic voltage regulator (AVR) according to VDE 0530, 400/230 volts, 4-pole, insulation class H.
Control Panel: manual start-stop-system with engine shutdown during monitoring, when low oil pressure (LOP), High temperate (HWT) and overspeed. Alternator switch, 3-pole with thermal and magnetic protection. Frequency meter, hours counter, voltmeter, ampere meter, optical and acoustic alarm. Electronic engine speed governor, AMF automatic control panel with ATS, for parallel operation with the mains supply or peak looping operation.
Tank: 24h fuel tank, automatic fuel-fill-system.
Trailer: 1 or 2 axle trailer.
Options: For all power generator is a wide range of accessories available.
Technical changes: We keep ahead.